节点文献

浅谈空调水系统同程和异程管网的选择

A Brief Talk on the Option of Reverse Return and Direct Return Mode for Air-conditioning Water System

  • 推荐 CAJ下载
  • PDF下载
  • 不支持迅雷等下载工具,请取消加速工具后下载。

【作者】 马婷婷王勇

【Author】 Ma Tingting;Wang Yong;Chongqing University;

【机构】 重庆大学

【摘要】 当空调系统末端水头损失接近,但流量相差较大且相距较远时,异程式水系统有可能更优于同程式水系统。通过空调水系统水力计算选取管网管径及水泵,利用环状管网水力计算与水力工况分析软件计算同程式水系统和异程式水系统中末端实际所得流量,对比两种管网布置方式的优劣,进而为实际空调水系统中同程与异程管网的选取提供一种新思路。

【Abstract】 When the head loss of the terminals in air-conditioning water system are closed,and the flow is quite different and far apart,direct return mode maybe superior to reverse return.Selecting pipe diameter and water pump of the air-conditiong water system by hydraulic calculation,and calculating the actual flow of terminals in reverse return mode and direct return mode for water system with Pipe Network Hydraulic Calculation and Hydraulic Condition analysis software program.Then making a comparison between two layout styles of pipeline,providing a new idea for the option of reverse return and direct return mode for air-conditioning water system.

  • 【会议录名称】 2015年第十六届西南地区暖通热能动力及空调制冷学术年会论文集
  • 【会议名称】2015年第十六届西南地区暖通热能动力及空调制冷学术年会
  • 【会议时间】2015-10-14
  • 【会议地点】中国四川绵阳
  • 【分类号】TU831.3
  • 【主办单位】四川省制冷学会空调热泵专业委员会、四川省土木建筑学会暖通热能专业委员会、中国勘察设计协会建筑环境与设备分会四川省委员会