【摘要】 本文采用实验方法研究了低温(-40℃)状态下复合绝热管高硅氧/酚醛复合材料内衬的NOL环强度和剪切强度,复合绝热管-界面的剪切强度,以及无损探伤。结果表明:低温历程对复合绝热管内衬材料的强度性能和界面粘接性能没有产生不利的后果。

【Abstract】 Cryogenic effects,including NOL ring strength,shear strength of the complex adiabatic tube liner made by glass fiber reinforce phenolic resin composite,and shear strength and NDI (non-destructive inspection) in the interface of the complex adiabatic tube had been studied in the experimental methods.No adverse results had been detected for the performances of the liner mechanics and interface integrality of the tube.