节点文献

铁-水体系电位-pH图与氧化性水工况的腐蚀控制

The corrosion control of the oxidative water condition and the potential-pH chart of the ferrum-water system

  • 推荐 CAJ下载
  • PDF下载
  • 不支持迅雷等下载工具,请取消加速工具后下载。

【作者】 谢学军吕珂张文晏敏潘玲龚洵洁彭珂如

【Author】 Xie Xuejun~1 Lv Ke~1 Zhang Wen~2 Yan Min~1 Pan Ling~1 (1-Dynamics and mechanism college of Wuhanuniversity,Wuhan,430072 2-Reservoir Territory Department of Changjiang Water Resource Committee)

【机构】 武汉大学动力与机械学院长江水利委员会库区处

【摘要】 目前超临界直流炉大都采用氧化性水工况,要求给水中铁的含量<10μg/L。为使超临界直流炉采用的氧化性水工况的腐蚀控制与铁-水体系的电位-pH 图统一,不能再以 10-6mol/L(即56μg/L)作为钢铁腐蚀与否的界限,而必须以 10-6.75mol/L(即10μg/L)作为腐蚀发生与否的界限,绘制铁-水体系的简化电位-pH 平衡图时必须在平衡计算中将离子浓度均取10-6.75mol/L(即10μg/L)。

【Abstract】 The super-critical once through boiler adopts oxidative water condition presently,and it is required that the ferrum ion content in the supplied water should be lower than 10μg/L.To unify the corrosion controlling of the oxidative water condition and the potential-pH chart of the ferrum-water system,it is considered that 10-6.75mol/L (namely 10μg/L) is more reasonable than 10-6mol/L (namely 56μg/L) to be the limit to judge the corrosion.At the same time,the potential-pH chart of ferrum-water system is drawn which ion content is chosen as 10-6.75mol/L (namely 10μg/L) in the balance calculation.

  • 【会议录名称】 湖北省电机工程学会电厂化学专委会2007年学术年会论文集
  • 【会议名称】湖北省电机工程学会电厂化学专委会2007年学术年会
  • 【会议时间】2007-09
  • 【会议地点】中国广东深圳
  • 【分类号】TM621.8
  • 【主办单位】湖北省电机工程学会电厂化学专委会
节点文献中: