Neutron leakage spectra benchmark of a spherical polyethylene sample with a252Cf fission source

  • 推荐 CAJ下载
  • PDF下载
  • 不支持迅雷等下载工具,请取消加速工具后下载。

【作者】 兰长林徐阔之魏玉婷聂阳波潘小东丁琰琰张时宇李昊南高波谢波阮锡超刘世龙

【Author】 Chang-Lin Lan;Kuo-Zhi Xu;Yu-Ting Wei;Yang-Bo Nie;Xiao-Dong Pan;Yan-Yan Ding;Shi-Yu Zhang;Hao-Nan Li;Bo Gao;Bo Xie;Xi-Chao Ruan;Shi-Long Liu;School of Nuclear Science and Technology, Lanzhou University;Key Laboratory of Nuclear Data, China Institute of Atomic Energy;

【机构】 School of Nuclear Science and Technology, Lanzhou UniversityKey Laboratory of Nuclear Data, China Institute of Atomic Energy

【摘要】 This paper presents the development and validation of China’s first benchmark measurement system for neutron leakage time-of-flight(TOF) spectra using a 252Cf spontaneous fission source and spherical polyethylene sample.EJ-309 and CLYC scintillation detectors were used for neutron detection,and a shadow cone was employed for background suppression.Notably,the SiC detector was,for the first time on this platform,applied as the starttime signal generator in TOF spectrum measurement.The TOF spectrum covering the energy range of 0.15-8.00MeV was measured,and the results were systematically compared with evaluated data from four major nuclear libraries:ENDF/B-Ⅷ.1,JEFF-3.3,JENDL-5,and CENDL-3.2.The comparison revealed strong agreement across the full spectrum,with calculated to experimental(C/E) deviations remaining within 5% in the high-energy region and within 13% at low energies.These results verify the system’s stability and suitability for integral experiments.The established benchmark platform provides a strong technical foundation for future neutron nuclear data validation,particularly in shielding applications and the improvement of fission-spectrum nuclear databases.

【Abstract】 This paper presents the development and validation of China’s first benchmark measurement system for neutron leakage time-of-flight(TOF) spectra using a 252Cf spontaneous fission source and spherical polyethylene sample.EJ-309 and CLYC scintillation detectors were used for neutron detection,and a shadow cone was employed for background suppression.Notably,the SiC detector was,for the first time on this platform,applied as the starttime signal generator in TOF spectrum measurement.The TOF spectrum covering the energy range of 0.15-8.00MeV was measured,and the results were systematically compared with evaluated data from four major nuclear libraries:ENDF/B-Ⅷ.1,JEFF-3.3,JENDL-5,and CENDL-3.2.The comparison revealed strong agreement across the full spectrum,with calculated to experimental(C/E) deviations remaining within 5% in the high-energy region and within 13% at low energies.These results verify the system’s stability and suitability for integral experiments.The established benchmark platform provides a strong technical foundation for future neutron nuclear data validation,particularly in shielding applications and the improvement of fission-spectrum nuclear databases.

【基金】 Supported by the Continuous-Support Basic Scientific Research Project (BJ010261223282)
  • 【文献出处】 Chinese Physics C ,中国物理C(英文) , 编辑部邮箱 ,2026年03期
  • 【分类号】TQ325.12;O571.5
  • 【下载频次】2