节点文献

Accuracy improvement of AC Stark shift microwave detection based on a “frequency ruler”

  • 推荐 CAJ下载
  • PDF下载
  • 不支持迅雷等下载工具,请取消加速工具后下载。

【作者】 刘帅; 李中豪; 李斌; 张立婷; 徐世宏; 孔静霞; 郭浩; 温焕飞; 马宗敏; 李鑫; 唐军; 刘俊;

【Author】 Shuai Liu;Zhonghao Li;Bin Li;Liting Zhang;Shihong Xu;Jingxia Kong;Hao Guo;Huanfei Wen;Zongmin Ma;Xin Li;Jun Tang;Jun Liu;State Key Laboratory of Widegap Semiconductor Optoelectronic Materials and Technologies, North University of China;State Key Laboratory of Extreme Environment Optoelectronic Dynamic Testing Technology and Instruments, Shanxi Province Key Laboratory of Quantum Sensing and Precision Measurement, North University of China;

【通讯作者】 李中豪;唐军;刘俊;

【机构】 State Key Laboratory of Widegap Semiconductor Optoelectronic Materials and Technologies, North University of China; State Key Laboratory of Extreme Environment Optoelectronic Dynamic Testing Technology and Instruments, Shanxi Province Key Laboratory of Quantum Sensing and Precision Measurement, North University of China;

【摘要】 The detection accuracy of frequency shift is crucial in microwave detection based on the Rydberg atomic alternating current(AC) Stark shift effect. We design a frequency shifter system that can provide a high-precision frequency reference signal and improve the detection accuracy of frequency shift. This system utilizes acoustic-optic modulators to generate two coupling lights with a fixed frequency interval and completes double Rydberg atomic excitation. The detection accuracy of the AC Stark shift(±1.33 MHz) is 6.08 times better than that of the wavelength meter-reading scheme(±8.09 MHz), and the minimum detectable frequency shift is improved by a factor of 3.13.

【Abstract】 The detection accuracy of frequency shift is crucial in microwave detection based on the Rydberg atomic alternating current(AC) Stark shift effect. We design a frequency shifter system that can provide a high-precision frequency reference signal and improve the detection accuracy of frequency shift. This system utilizes acoustic-optic modulators to generate two coupling lights with a fixed frequency interval and completes double Rydberg atomic excitation. The detection accuracy of the AC Stark shift(±1.33 MHz) is 6.08 times better than that of the wavelength meter-reading scheme(±8.09 MHz), and the minimum detectable frequency shift is improved by a factor of 3.13.

【基金】 supported by the National Natural Science Foundation of China (Nos. 52435011, 51821003, 62103385, and 62175219);the Joint Funds of the National Natural Science Foundation of China (No. U21A20141)
  • 【文献出处】 Chinese Optics Letters ,中国光学快报(英文版) , 编辑部邮箱 ,2025年07期
  • 【分类号】O562;O43
  • 【下载频次】2
节点文献中: