ICP-MS法测定盐酸安舒法辛缓释片中7个元素杂质含量
Determination of 7 kinds of elemental impurities in desvenlafaxine hydrochloride extended-release tablets by ICP-MS
【摘要】 目的:建立电感耦合等离子体质谱(ICP-MS)法测定盐酸安舒法辛缓释片中铅(Pb)、镉(Cd)、砷(As)、汞(Hg)、钴(Co)、钒(V)、镍(Ni)7个元素杂质含量。方法:用微波消解进行样品前处理;以73Ge,115In,209Bi为内标,采用ICP-MS进行测定,测量模式为碰撞池模式(KED),碰撞气流速4.35 mL·min-1,采样深度5.0 mm,辅助气流速0.8 L·min-1,雾化器流速1.075 L·min-1;对所建立的方法进行了方法学验证。结果:7个元素标准曲线的相关系数均大于0.99;加样回收率在92.2%~104.4%之间;重复性试验RSD≤1.2%(n=6);中间精密度试验RSD≤3%,均满足USP<233>方法学验证的要求。样品检测的结果远小于国际人用药物注册技术协调会议《元素杂质指南Q3D》(ICHQ3D)中各元素杂质的每日允许暴露量(PDE)。结论:本文建立的方法样品用量少,分析速度快,灵敏度高,可用于盐酸安舒法辛缓释片中元素杂质的质量研究。
【Abstract】 Objective:To establish an inductively coupled plasma mass spectrometry(ICP-MS)method for determination of 7 kinds of elemental impurities(Pb,Cd,As,Hg,Co,V,Ni)in desvenlafaxine hydrochloride extended-release tablets.Methods:Microwave digestion was adopted for sample pretreatment.73Ge,115In,209Bi were chosen as internal standard elements,and an inductively coupled plasma mass spectrometry method was established with following conditions:measurement mode was collision cell mode with kinetic energy discrimination(KED),the Q Cell gas was 4.35 mL·min-1,the sampling depth was 5.0 mm,the auxilliary flow was 0.8 L·min-1 and the nebulizer flow was 1.075 L·min-1.The method was validated.Results:Regression coefficients of standard curve of those seven elemental impurities are beyond 0.99.The recovery rates of spiked samples ranged from 92.2% to 104.4%.In repeatability,the RSD ≤ 1.2%(n=6).The RSD ≤ 3% of intermediate precision test.The determined values were well below permitted daily exposure(PDE)of elemental impurities in International Conference on Harmonization of Technical Requirements for Registration of Pharmaceuticals for Human Use < Guideline For Elemental Impurities Q3D>(ICHQ3D).Conclusion:The microwave digestion-ICP-MS method has a high sensitivity,a strong specificity,a fast analysis speed,and it only requires a small amount of sample which can support the determination of 7 elements in desvenlafaxine hydrochloride extended-release tablets.
【Key words】 elemental impurities; desvenlafaxine hydrochloride extended-release tablets; ICP-MS; USP<233>; ICHQ3D; method validation;
- 【文献出处】 药物分析杂志 ,Chinese Journal of Pharmaceutical Analysis , 编辑部邮箱 ,2019年02期
- 【分类号】R927.2
- 【被引频次】9
- 【下载频次】453