节点文献

入池酒醅酸度测定结果的不确定度评定

Evaluation of Uncertainty in the Determination of Acidity of Fermented Grains

  • 推荐 CAJ下载
  • PDF下载
  • 不支持迅雷等下载工具,请取消加速工具后下载。

【作者】 宰红玉; 汤有宏; 万春环;

【Author】 ZAI Hongyu;TANG Youhong;WAN Chuanhuan;Anhui Gujing Gongjiu Co.,Ltd.;Anhui Runanxinke-Test Technology Co.,Ltd.;

【机构】 安徽古井贡酒股份有限公司; 安徽润安信科检测科技有限公司;

【摘要】 对入池酒醅酸度的整个测定过程进行不确定度的来源评定与量化,找出引起不确定度的主要因素,最终评定影响测定结果的主要因素有样品的重复性测定、滴定管、量筒量取浸泡试样的蒸馏水体积、氢氧化钠标准滴定溶液、吸取滤液的分度吸管。本次入池酒醅度测定的扩展不确定度为0.1034mL/g。

【Abstract】 The assessment of the source of uncertainty and quantification of the acidity of the wine into the pool to identify the main factors that cause uncertainty, the final assessment of the main factors affecting the determination of the results of the sample repeatability, burettes, measuring the amount of cylinder Soak the distilled water volume of the sample, sodium hydroxide standard titration solution, draw the filtrate indexing pipette. The expansion of the determination of the pool wine uncertainty of 0.1034 mL/g.

【关键词】 入池酒醅酸度; 不确定度; 评定;
【Key words】 Into the pool wine acidity; uncertainty; assessment;
  • 【文献出处】 酿酒 ,Liquor Making , 编辑部邮箱 ,2018年05期
  • 【分类号】TS261.4
  • 【被引频次】4
  • 【下载频次】86
节点文献中: