Fenton+MnO2+A/O组合工艺处理过氧化甲乙酮生产废水
Treatment of methylethyl ketone peroxide processing wastewater by combined process,Fenton+MnO2+A/O
【摘要】 利用Fenton+MnO2+A/O组合工艺处理过氧化甲乙酮生产废水。在Fenton+MnO2预处理阶段对影响废水COD去除率的主要因素进行了考察,得到反应的最佳条件:p H=2.7,30%H2O2投加量为0.1 L/L,FeSO4·7H2O投加量为5 g/L,MnO2投加量为8 g/L,MnO2氧化反应时间为45 min。废水经Fenton+MnO2氧化预处理后可生化性由0.14提高到了0.25左右。废水经Fenton+MnO2+A/O组合工艺处理后,出水COD稳定低于500 mg/L。
【Abstract】 The combined process,Fenton+MnO2+A/O has been used for treating methylethyl ketone peroxide processing wastewater. The key factors affecting the wastewater COD removing rate in the stage of Fenton+MnO2 pretreatment are investigated. The results show that the optimum conditions are as follows:the p H is 2.7,dosage of 30% of H2O2 0.1 L/L,dosage of FeSO4·7H2O 5 g/L,dosage of MnO28 g/L,and MnO2 oxidation reaction time 45 min. After the wastewater has been pretreated by Fenton+MnO2 oxidation process,its biodegradability can be improved from 0.14 to about 0.25. After the wastewater has been treated by Fenton+MnO2+A/O process,the effluent COD is stably lower than 500 mg/L.
【Key words】 methylethyl ketone peroxide processing wastewater; Fenton; MnO2; A/O process;
- 【文献出处】 工业水处理 ,Industrial Water Treatment , 编辑部邮箱 ,2016年02期
- 【分类号】X783
- 【下载频次】153