节点文献
超高压液相色谱-串联质谱法对马口铁罐内涂层中双酚A及其模拟迁移的测定
Determination of bisphenol A migration from inside coating of tinplate can by ultra perssure liquid chromatography-tandem mass spectrometry
【摘要】 目的建立了超高压液相色谱-串联质谱法测定马口铁罐内涂层中双酚A迁移含量的方法。方法样品经模拟溶液提取后用C18色谱柱分离,UPLC-MS/MS多反应监测模式下进行定性定量分析,并对金属制品内涂层双酚A在不同食品模拟物环境下的迁移行为进行了研究。结果线性范围为5.0~100.0μg/L,最低检测浓度为1.0μg/L,回收率为78.6%~86.2%,相对标准偏差为7.3%~12.6%。结论双酚A迁移水平受模拟物性质影响,相对于水性模拟物,在醇溶性模拟物中更易发生迁移。双酚A迁移水平随迁移试验温度和接触时间的增加而升高。
【Abstract】 Objective An ultra high pressure liquid chromatography (UHPLC)-mass spectrometry/mass spectrometry (MS/MS) method has been established for determination of bisphenol A (BPA) migration content in coating tinplate tank. Methods The different simulation extraction solutions were separated with C 18 chromatographic column, and were qualitatively and quantitatively analyzed with UPLC-MS/MS. The migration behavior of free BPA in metal food packaging material in different food simulation solution was studied. Results The method linear range was 5.0~100.0 μg/L, the minimum detection concentration was 1.0 μg/L, the recovery was 78.6%~86.2%, and the relative standard deviation was 7.3%~12.6%. Conclusion The migration behavior of BPA is affected by the nature of simulation solution properties. Compared with water-based analog, the more migration will curred in alcohol-soluble simulation solution. The migration level of BPA will be increased with increase of temperature and contaction time.
【Key words】 ultra high pressure liquid chromatography-tandem mass spectrometry; bisphenol A; tinplate cans; migration; determination;
- 【文献出处】 食品安全质量检测学报 ,Journal of Food Safety & Quality , 编辑部邮箱 ,2013年04期
- 【分类号】R155.5
- 【被引频次】8