多中心临床研究:采用X线衰减校正提高99mTc-3PRGD2肺癌SPECT图像定量分析精确性

Multicenter clinical study:the use of X-ray attenuation correction to improve quantitative analysis precision for 99mTc-3PRGD2 lung cancer SPECT image

  • 推荐 CAJ下载
  • PDF下载
  • 不支持迅雷等下载工具,请取消加速工具后下载。

【作者】 杨爱民石希敏戴皓洁辛军赵新民王喆郑山高蕊李眉缪蔚冰赵周社贾兵朱朝晖汪静吴文凯李方

【Author】 YANG Ai-min1,SHI Xi-min2,DAI Hao-jie3,XIN Jun4,ZHAO Xin-min5,WANG Zhe6,ZHENG Shan7,GAO Rui1,LI Mei3,MIAO Wei-bing7,ZHAO Zhou-she8,JIA Bing9,ZHU Zhao-hui2,WANG Jing5,WU Wen-kai10,LI Fang2(1.Department of Nuclear Medicine,the First Affiliated Hospital of Xian Jiaotong University,Xian 710061,China;2.Department of Nuclear Medicine,Peking Union Medical College Hospital,Beijing 100032,China;3.Department of Nuclear Medicine,Beijing Tongren Hospital,Beijing 100730,China;4.Department of Nuclear Medicine,the Affiliated Shengjing Hospital of China Medical University,Shenyang 110004,China;5.Department of Nuclear Medicine,the Fourth Hospital of Hebei Medical University,Shijiazhuang 050011,China;6.Department of Nuclear Medicine,Xijing Hospital of the Fourth Military Medical University,Xian 710032,China;7.Department of Nuclear Medicine,the First Hospital of Fujian Medical University,Fuzhou 350005,China;8.GE Healthcare(China),Beijing 100176,China;9.Medical Isotopes Research Center of Beijing University,Beijing 100191,China;10.Department of Nuclear Medicine,Cancer Hospital,Peking Union Medical College,Chinese Academy of Medical Sciences,Beijing 100021,China)

【机构】 西安交通大学医学院第一附属医院核医学科北京协和医院核医学科北京同仁医院核医学科中国医科大学附属盛京医院核医学科河北医科大学第四医院核医学科第四军医大学西京医院核医学科福建医科大学附属第一医院核医学科美国通用电气医疗系统集团(中国)北京大学同位素研究中心中国医学科学院肿瘤医院核医学科

【摘要】 目的:采用X线衰减校正提高前瞻性、多中心研究中99mTc-3PRGD2肺癌SPECT图像定量分析的精确性。方法:经病理确诊的肺癌患者27例,其中肺腺癌23例、鳞癌4例。患者静脉注射99mTc-3PRGD2后40分钟顺序进行全身和局部断层扫描。采用迭代图像重建方法,对获得的99mTc-3PRGD2SPECT图像进行X线衰减校正(CTAC)和非衰减校正重建(NAC)。测量CTAC和NAC病灶所在层面的总计数,感兴趣区域(ROI)病灶的总计数、最大计数和平均计数。分别以病灶ROI内最大计数的38%、42%和48%作为阈值测量CTAC和NAC图像病灶最大长径。结果:经过CTAC后病灶所在层面总计数增加2.09倍,ROI区域病灶的总计数增加3.32倍,病灶最大计数和平均计数与本底比值分别提高了65.9%和70.3%。以病灶ROI最大计数42%作为阈值,CTAC后的病灶最大长径为(5.65±2.77)cm,与CT测量结果一致。结论:采用X线衰减校正是提高99mTc-3PRGD2定量分析的有效方法。

【Abstract】 Objective: Using X-ray attenuation correction to improve a prospective,multicenter study of 99mTc-3PRGD2 SPECT image quantitative analysis precise in lung patients.Methods: 27 patients,adenocarcinoma of 23 cases and squamous cell carcinoma of 4 cases,diagnosed by pathology.Images of whole body scan and local tomography were obtained after 99mTc-3PRGD2 injection of 40 minutes intravenously.Iterative image reconstruction method was used to obtain the X-ray attenuation correction(CTAC) and no attenuation correction reconstruction(NAC) on the basis of 99mTc-3PRGD2 SPECT images.Total count of the lesions slice,total count,maximum and average count of the region of interest(ROI) were extracted individually from the slices of CTAC and NAC frames.The maximum count 38%,42% and 48% within ROI were chosed as the threshold to measure the diameter length of CTAC and NAC image focus.Results: The results showed that after CTAC,the total count,of the focus slice was increased 2.09 times,the total count of the ROI was increased 3.32 times,maximum and mean counts and the background ratio were increased by 65.9% and 70.3%,individually.With the maximum count 42% of the lesion ROI as the threshold,the lesions maximum size was of(5.65±2.77) cm after CTAC,which is coincidence with CT measurement results.Conclusion: Using X-ray attenuation correction helps to improve 99mTc-3PRGD2 quantitative analysis.

【基金】 国家自然科学基金项目(81171369)
  • 【文献出处】 中国临床医学影像杂志 ,Journal of China Clinic Medical Imaging , 编辑部邮箱 ,2013年05期
  • 【分类号】R734.2
  • 【被引频次】1
  • 【下载频次】141