【作者】 韩鹏武玉王小明刘华军蔡登刚郭亮许成成

【Author】 Han Peng,Wu Yu,Wang Xiaoming,Liu Huajun,Cai Denggang,Guo Liang,Xu Chengcheng(Institute of Plasma Physics,Chinese Academy of Sciences,Hefei 230031,China)

【机构】 中国科学院等离子体物理研究所

【摘要】 国际热核聚变实验反应堆(ITER)磁体环场线圈TF导体采用CICC(cable in conduit conductor)导体结构,其导管为316LN型不锈钢套管。文中针对ITER项目对导体气密性要求,主要介绍了超导体导管焊缝的氦质谱气密性检测技术方法、检测系统、检测流程和漏率计算。

【Abstract】 The toroidal magnet system of the International Thermonuclear Experimental Reactor(ITER) was made of TF conductor that was used CICC(cable in conduit conductor) structure,316LN stainless steel tube was used as ITER TF conductor jacket.According to ITER requirement of the conductor tightness,this paper mainly introduced the helium mass spectrometry tightness test method,test system,test process and the leakage rat calculated on welded joints of TF conductor jacket.

【关键词】 CICC导体气密性检测ITER
【Key words】 CICC conductorLeak testITER