节点文献

两种脱氮除磷污水处理工艺的效果分析

Efficiency Analysis of Two Sewage Treatment Processes for Nitrogen and Phosphorus Removal

  • 推荐 CAJ下载
  • PDF下载
  • 不支持迅雷等下载工具,请取消加速工具后下载。

【作者】 沈连峰胡宗泰王婷张发文李有

【Author】 SHEN Lian-feng1,HU Zong-tai2,WANG Ting1,ZHANG Fa-wen1,LI You1(1.Department of Environmental Engineering,Henan Agricultural University,Zhengzhou 450002, China;2.Zhengzhou Sewage Purification Company,Zhengzhou 450001,China)

【机构】 河南农业大学环境工程系郑州市污水净化公司

【摘要】 结合郑州市马头岗污水处理厂的运行情况,对比分析了倒置A2/O工艺与UCT工艺的运行效果。结果表明,倒置A2/O工艺与UCT工艺对污水中COD、BOD5、SS、NH3-N的去除效果并无明显差异,两种工艺对这些指标的去除率都较高,月平均去除率都能达到90%以上,但两种工艺对TP和TN的去除效果略有差异,倒置A2/O工艺对TP和TN的去除率高于UCT工艺主要是受进水碳源和混合液回流等条件影响所致。

【Abstract】 Based on the running conditions of Matougang Sewage Treatment Plant,the comparative analysis of operation efficiency between the reversed A2/O process and the UCT process was performed.The results show that there is no significant difference in removal of COD,BOD5,SS and NH3-N.In the two processes,the removal rates of these indicators are higher,and the monthly average removal rates can reach more than 90%.However,the two processes have slight difference in the removal of TP and TN.The removal rates of TP and TN in the reversed A2/O process are higher than those in the UCT process,which is due to the influence of influent carbon source and mixed liquid return.

  • 【文献出处】 中国给水排水 ,China Water & Wastewater , 编辑部邮箱 ,2011年12期
  • 【分类号】X703.1
  • 【被引频次】6
  • 【下载频次】452