节点文献
燃煤电厂干式贮灰场防渗设计探讨
A Study of Anti-seepage Design for Ash Area of Fossil Fuel Power Plant
【摘要】 干式贮灰场可能引起的环保问题主要有对地下水、地表水、扬尘、噪声等,其中对地下水的影响往往更严重。对干式贮灰场进行防渗处理,是避免污染地下水环境,达到环保标准的重要方法。以此为思路,探讨了灰场可能污染方式、干灰场防渗的规定、作法,并对扩建灰场的防渗问题进行了深入探讨。
【Abstract】 Problems caused by a dry ash disposal area include the pollution of underground water,the pollution of ground water,the pollution of fugitive dust and noise during construction,of which the pollution of underground water is the most serious hazard.To prevent underground water from being contaminated and to meet the environmental standard,anti-seepage system is the important design for dry ash disposal area.Possible pollution types,environmental standards and practice and anti-seepage system design for extensive ash disposal area are discussed in the paper.
【关键词】 干式贮灰场;
地下水;
污染;
防渗;
土工膜;
【Key words】 dry ash disposal area; underground water; pollution; anti-seepage; geo-membrane;
【Key words】 dry ash disposal area; underground water; pollution; anti-seepage; geo-membrane;
- 【文献出处】 国土资源科技管理 ,Scientific and Technological Management of Land and Resources , 编辑部邮箱 ,2011年06期
- 【分类号】TU463
- 【被引频次】2