节点文献

胶束电动毛细管电泳法测定维生素B4

Determination of vitamin B4 by micellar electrokinetic capillary chromatography

  • 推荐 CAJ下载
  • PDF下载
  • 不支持迅雷等下载工具,请取消加速工具后下载。

【作者】 唐俊张晓丽刘二保

【Author】 TANG Jun,ZHANG Xiaoli,LIU Erbao(Lab of Water Resources and Water Environment,Tianjin Normal University,Tianjin 300387,China)

【机构】 天津师范大学水资源与水环境实验室

【摘要】 采用胶束电动毛细管电泳(MEKC)法测定维生素B4的含量,电泳缓冲液为2.0×10-2mol/L硼砂-硼酸缓冲液(pH=8.4),含2.5%(V/V)甲醇及10 mmol/L十二烷基硫酸钠(SDS),在电泳电压20 kV和检测波长254 nm的条件下,维生素B4具有最佳的迁移时间和峰形;考察了缓冲溶液的pH、浓度、有机改性剂及胶束对维生素B4迁移行为的影响.结果表明:维生素B4在8.0×10-7~5.0×10-5mol/L内成良好的线性关系(r=0.999 9),方法的检出限为1.2×10-7mol/L,RSD为2.24%,该法已成功用于药剂、血清和尿液中维生素B4的测定.

【Abstract】 A method for the detection of vitamin B4(VB4) by capillary zone electrophoresis was presented.The electrophoresis running buffer was 40 mmol/L of borax borate solution(pH 8.4),2.5%(V/V) methanol and sodium dodecyl sulfate(SDS) of 10 mmol/L.VB4 had best peak shape and migration time,under the conditions of the voltage of 20 kV and the detection wavelength of 254 nm.Quantitative analysis showed that the linear relationship between the concentration and peak area was good(r≥0.999 9).In addition,the effect of buffer pH,concentration,organic modifier agents and the micellar on VB4 migration behaviors of the solutes were also invested.The results showed that VB4 had a good linear relationship during 8.0×10-7—5.0×10-5 mol/L,r=0.999 9,RSD was 2.24%.The detection limit was 1.2×10-7 mol/L.This method was successfully used for the medicine,serum and fluid metabolism of adenine.

【基金】 天津自然科学基金资助项目(08JCYBJC02800)
  • 【文献出处】 天津师范大学学报(自然科学版) ,Journal of Tianjin Normal University(Natural Science Edition) , 编辑部邮箱 ,2009年03期
  • 【分类号】R927
  • 【被引频次】4
  • 【下载频次】124
节点文献中: