【作者】 赵晓亚李娟林雁飞胡小钟王鹏付晓芳李晶

【Author】 ZHAO Xiao-ya1,LI Juan2,LIN Yan-fei1,HU Xiao-zhong1,WANG Peng1,FU Xiao-fang1,LI Jing1 (1.Technology Center of Hubei Entry-Exit Inspection and Quarantine Bureau,Wuhan 430022,China;2.Department of Pharmacy,Tongji Hospital,Tongji Medical College,Huazhong University of Science and Technology,Wuhan 430030,China)

【机构】 湖北出入境检验检疫局技术中心华中科技大学同济医学院附属同济医院药学部

【摘要】 建立了化妆品中四环素、土霉素、金霉素、强力霉素、甲烯土霉素、去甲基金霉素、二甲胺四环素、脱水四环素和差相四环素含量的液相色谱串联质谱测定方法。对提取溶剂、流动相、流动相的梯度以及质谱参数进行了研究。采用乙腈-甲醇-草酸水溶液提取,LC-MS/MS分离测定,样品中被测物与干扰物能得到良好的分离。甲烯土霉素、去甲基金霉素在0.05~10.0 mg/L范围内其质量浓度与峰面积均呈良好的线性关系,其余7种化合物在0.01~10.0 mg/L范围内其质量浓度与峰面积呈良好的线性关系。添加1.0~50.0 mg/kg时的加标回收率为73%~99%,相对标准偏差低于13.2%。该法简便、快速、准确,可用于化妆品中上述9种四环素类药物的定性、定量检测。

【Abstract】 A high performance liquid chromatography tandem mass spectrometry(HPLC-MS/MS) method was established for the determination of 9 tetracyclines including tetracycline,oxytetracycline,chlorotetracycline,doxycycline,metacycline,demeclocycline,minocycline,anhydrotetracycline,4-epitetracycline in cosmetics.The effects of different extraction reagent,flow phase,gradient and tandem mass spectrometry parameters were investigated.The sample was extracted with methanol-acetonitrile-oxalic acid solution.The separation of analytes was performed on a C18 column with a gradient elution using water,methanol,acetonitrile and 0.5% formic acid solution as mobile phase.The external standard calibration curve was used for quantification.There were good linear relationship between peak areas and concentrations in the range of 0.05-10.0 mg/L for metacycline and demeclocycline,and 0.01-10.0 mg/L for rest of analytes.The correlation coefficients were more than 0.999.The spiked recoveries were 73%-99% with relative standard deviations(RSDs) less than 13.2%.This method was simple,fast,accurate and convenient and could be used as one of the reliable means for quantitative determination of tetracyclines in cosmetics.

【关键词】 化妆品四环素类液相色谱-串联质谱
【Key words】 cosmetictetracyclineHPLC-MS/MS
【基金】 国家质检总局重大项目资助(2008IK257)
  • 【文献出处】 分析测试学报 ,Journal of Instrumental Analysis , 编辑部邮箱 ,2009年10期
  • 【分类号】O657.63;TQ658