节点文献
菏泽电厂深度调峰运行机组安全经济性分析及改进措施
SAFETY AND ECONOMIC ANALYSIS OF UNITS USED FOR DEEP PEAK-REGULATING OPERATION IN HEZE POWER PLANT AND RETROFIT MEASURES THEREOF
【摘要】 对国电菏泽发电厂2×300MW、2×330MW机组参与100MW负荷的调峰运行进行了安全经济性分析,并提出了相应的运行措施。该厂自2006年以来共参与了60余次深度调峰运行,累计节油400多t,直接经济效益约240万元。
【Abstract】 A safety and economic analysis of 2×300 MW units and 2×330 MW units participating in peak-regulating operation for a load of 100 MW has been carried out,and the corresponding operation measure being proposed.Consecutively deepening the peak-regulating operation of said units,the effectiveness of energy-saving and emission-reducing is remarkable.In 60 times of participation into deep peak-regulating operation,the accumulatively saved oil reaches more than 400 t,the direct economic benefits being about RMB 2.4 million yuan.
【关键词】 300MW机组;
330MW机组;
深度调峰运行;
安全经济性;
【Key words】 300 MW unit; 330 MW unit; deep peak-regulating operation; safety economic behavior;
【Key words】 300 MW unit; 330 MW unit; deep peak-regulating operation; safety economic behavior;
- 【文献出处】 热力发电 ,Thermal Power Generation , 编辑部邮箱 ,2009年10期
- 【分类号】TM621
- 【被引频次】9
- 【下载频次】368