节点文献

大型煤粉锅炉燃烧器区域水冷壁近壁烟气气氛调整改善

Adjustment and Improvement on Burner Area Furnace Near-wall Reducing Flue Gas for Coal Firing Boiler

  • 推荐 CAJ下载
  • PDF下载
  • 不支持迅雷等下载工具,请取消加速工具后下载。

【作者】 刘林波Manfred Ochlast鲍宇轩符俊平李斌

【Author】 LIU Lin-bo, Manfred Ochlast, BAO Yu-xuan, FU Jun-ping, LI Bin

【机构】 湖北省电力试验研究院E.ON Engineering GmbH

【摘要】 煤粉锅炉水冷壁近壁还原性气氛是造成水冷壁高温腐蚀的重要原因。首先介绍了对上海锅炉厂1025t/h锅炉水冷壁近壁气氛的测试及水冷壁高温腐蚀倾向评估情况,而后阐述了为改善水冷壁近壁还原性气氛开展的调整试验工作,调整试验工作使水冷壁近壁还原性气氛得到了改善,而后根据测试及调整情况进行了分析并提出了相关建议。

【Abstract】 Furnace near-wall reducing flue gas is the most important cause leading to boiler furnace high temperature corrosion. It first introduces the furnace near-wall flue gas measurement and high temperature corrosion tendency evaluation for 1025t/h boiler made by Shanghai Boiler Plant, and then expatiates on the adjustment work for improving furnace near-wall reducing flue gas, the adjustment work has improved the boiler furnace near-wall reducing flue gas, at last analyzes the furnace flue gas status basing on measurement and adjustment work, and gives correlative suggestions for the boiler.

  • 【文献出处】 电站系统工程 ,Power System Engineering , 编辑部邮箱 ,2009年01期
  • 【分类号】TK229.6
  • 【被引频次】5
  • 【下载频次】187