氢化物发生-原子荧光光谱法测定铅的最佳酸度条件选择
Choice of optimal acidity condition on determination of lead by hydride generation atomic fluorescence spectrometry
【摘要】 目的:对氢化物发生-原子荧光光谱法测定铅的酸度介质条件进行分析和研究,选择出最适宜的盐酸介质条件。方法:通过在不同的盐酸介质条件下对铅的标样进行测定。结果:酸度对铅测定的荧光强度有非常大的影响,在合适的酸度范围下进行铅的测定,能获得较高的灵敏度和精密度。结论:以2.0%盐酸作载流,在1.6%~2.5%的较宽的盐酸浓度范围内,测定铅能提高荧光强度,且获得5%以内的相对标准偏差。
【Abstract】 Objective:The optimal acidity condition on determination of lead by hydride generation atomic fluorescence spectrometry was given by studying the different acidity condition of hydrochloric acid.Methods:Test sample of lead in different acidity condition of hydrochloric acid.Results:It was found that the acidity has great impact to the fluorescence intensity on determination of lead.Within the appropriate acidity scope it comes with a higher accuracy and sensitivity result.Conclusion:Within the wider hydrochloric acid concentration scope of 1.6% to 2.5%,the fluorescence intensity on determination of lead by hydride generation atomic fluorescence spectrometry can be raised and acquire 5% of opposite and standard deviation with carrier of 2.0% hydrochloric acid.
- 【文献出处】 中国卫生检验杂志 ,Chinese Journal of Health Laboratory Technology , 编辑部邮箱 ,2007年07期