Tenax采样管富集气相色谱-质谱法测定空气中的痕量酚类化合物

Determination of Trace Phenol Compounds Using Gas Chromatography-Mass Spectrometry Coupled with Tenax Adsorption Tube for Enrichment of Air Samples

  • 推荐 CAJ下载
  • PDF下载
  • 不支持迅雷等下载工具,请取消加速工具后下载。

【作者】 杨丽莉胡恩宇母应锋纪英

【Author】 YANG Lili,HU Enyu,MU Yingfeng,JI Ying (Nanjing Environment Monitoring Center,Nanjing 210013,China)

【机构】 南京市环境监测中心站南京市环境监测中心站 江苏南京210013江苏南京210013

【摘要】 建立了Tenax采样管富集气相色谱-质谱测定空气中痕量酚类化合物的方法。用Tenax采样管吸附环境空气中的痕量酚类化合物,用甲醇淋洗解吸酚类化合物,洗脱液加入萘-D8作为内标,利用气相色谱-选择离子监测质谱(GC-M S/S IM)进行检测,内标法定量。该方法定性、定量准确,线性响应良好,回归曲线的线性相关系数均大于0.999,平均回收率为92.4%~102%,测定干扰小,检测灵敏度高,按采样10L计算,空气中最低检测浓度可达0.001m g/m3。用于实际样品测定,完全能满足环境空气中痕量酚类化合物监测的要求。

【Abstract】 A novel determination method for trace of seven phenol compounds in air samples has been established.They were collected with Tenax adsorption tube(180 mm×60 mm glass tube packed with 150 mg Tenax(40-60 mesh)) and desorbed with methanol.Five microlitres of naphthalene-D8(internal standard) solution was added to the eluate.One microlitre of the mixture solution was injected into an HP-5MS capillary column(30 m×0.25 mm×0.25 μm) and determined by gas chromatography-mass spectrometry with selected ion monitoring(GC-MS/SIM).The selected ions were m/z 94,95,66,108,107,77,90,122,121,107 and 136.The quantitative ions,m/z 94 for phenol,m/z 108 for cresol,m/z 122 for xylenol and m/z 136 for internal standard,were selected.The average recoveries of phenol compounds(spiked at the levels of 0.25,1.00,5.00 μg) ranged from 92.4% to 102% and the relative standard deviations were less than 4.8%.When the air sample volume was 10 L,the detection limits were less than 0.001 mg/m3.Good linearities were observed in the range from 0.05 to 20.0 mg/L.The method is simple,fast,sensitive and accurate for the determination of phenol compounds in air samples.

【基金】 江苏省大型科学仪器设备共享服务平台理事会资助项目(江苏省科学技术厅(苏科条函(2006)57号)
  • 【文献出处】 色谱 ,Chinese Journal of Chromatography , 编辑部邮箱 ,2007年01期
  • 【分类号】O657.63;X831
  • 【被引频次】34
  • 【下载频次】460