反相高效液相色谱法测定冬枣中噻菌铜的农药残留

Determination of Thiodiazole Copper Residues in Winter Date by RP-HPLC

  • 推荐 CAJ下载
  • PDF下载
  • 不支持迅雷等下载工具,请取消加速工具后下载。

【作者】 赵善仓; 邓立刚; 赵领军; 毛江胜; 赵平娟;

【Author】 ZHAO Shan-cang1,DENG Li-gang1,ZHAO Ling-jun2,MAO Jiang-sheng1,ZHAO Ping-juan1 (1.Inspection Center of Food Quality (Jinan)Ministry of Agriculture,Jinan 250100,China; 2.Jinan Agriculture Information Center,Jinan 250002,China)

【机构】 农业部食品质量监督检验测试中心; 济南市农业信息中心; 农业部食品质量监督检验测试中心 济南250100; 济南250100; 济南250002;

【摘要】 采用硫化钠水解,Amberlite XAD-7树脂吸附,DMF洗脱,建立冬枣中噻菌铜残留的反相高效液相色谱(HPLC-UV)测定方法。流动相为乙腈-0.1%乙酸水溶液(体积比12∶88),试验结果表明,该方法具有很好的线性关系与精密度。

【Abstract】 A reversed-phase high performance liquid chromatographic method (HPLC)was established for determina-tion of thiodiazole copper residues in winter date. Samplers were hydrolyzed by Na2S. Amberlite XAD-7 resin absorption,eluted with DMF. The system use acetonitrile + 0.1% acetic acid aqueous solution as mobile phase (12∶88,by vol). There was a good linear relationship between the content of component and its peak area. The method can be used for determination of thiodiazole copper residues in winter date.