600MW超临界机组给水泵密封水回收

Sealing Water Recovery of Feed Water Pumps of a 600 MW Supercritical Power Generating Set

  • 推荐 CAJ下载
  • PDF下载
  • 不支持迅雷等下载工具,请取消加速工具后下载。

【作者】 庄建华王福玉

【Author】 ZHUANG Jian-hua,WANG Fu-yu(Engineering Department,Guohua Taicang Power Generation Co.Ltd.,Taicang 215433,China)

【机构】 国华太仓发电有限公司工程部国华太仓发电有限公司工程部 江苏太仓215433江苏太仓215433

【摘要】 国华太仓发电有限公司600 MW机组自投运以来,多次出现凝汽器真空缓降的现象,当时机组负荷不大且系统严密性合格。经分析认为是给水泵组密封水回水不畅影响了凝汽器真空。提出了改造的措施,并解决了这一问题,以后机组运行稳定。

【Abstract】 Slow drop of vacuum has frequently appeared to a 600MW power unit’s condenser in Guohua Taicang Power Generation Co.Ltd.since it was put into operation,during which the unit load was found to be not high and the sealing system sound.Based on analysis,it is believed that the problem was caused by blocked returning of sealing water in the water pump.Countermeasures were proposed and taken and hence the problem solved and stable operation obtained.

  • 【文献出处】 发电设备 ,Power Equipment , 编辑部邮箱 ,2007年02期
  • 【分类号】TM621.3