300MW氢冷发电机定子绕组出水温升异常分析

Analysis of the Abnormal Temperature Rise of a 300 MW Turbogenerator’s Stator Winding Issue Coolant

  • 推荐 CAJ下载
  • PDF下载
  • 不支持迅雷等下载工具,请取消加速工具后下载。

【作者】 王云峰; 薛长海; 付强; 刘体新;

【Author】 WANG Yun-feng,XUE Chang-hai,FU Qiang,LIU Ti-xin(Jiaozuo Power Plant,Jiaozuo 454001,China)

【机构】 焦作电厂; 焦作电厂 河南焦作454001; 河南焦作454001;

【摘要】 本文针对一起300MW汽轮发电机运行时定子线圈出水温升异常现象,从理论到实际,全面地分析了故障发生的原因,讲述了处理的方法,并对发电机生产厂家提出了改进建议,对该发电机配套内冷水系统的结构布局及原部颁发电机运行规程提出了修改意见。

【Abstract】 Based on the phenomenon of the abnormal temperature rise of a 300MW turbogenerator’s stator winding issue coolant during operation,this paper provided a comprehensive analysis of the cause and solution.It also gave improve proposals about the generator’s coolant system composition to its manufactures.It also gave amending suggestions to the operation regulations of the generator issued by the State Electric Company.

【关键词】 定子; 出水; 温升;
【Key words】 stator; issue coolant; temperature rise;
  • 【文献出处】 大电机技术 ,Large Electric Machine and Hydraulic Turbine , 编辑部邮箱 ,2007年01期
  • 【分类号】TM311
  • 【被引频次】4
  • 【下载频次】95