节点文献
反相高效液相色谱法测定注射用别嘌醇钠的含量
Determination of aliopurinol in ailopurinol sodium for injection by RP-HPLC
【摘要】 目的:建立测定反相高效液相色谱法测定注射用别嘌醇钠的含量。方法:采用C18色谱柱(250mm×4.6 mm,5μm);0.125%磷酸二氢钾-甲醇(95:5)为流动相;柱温为30℃;流速为1.0mL·min-1;检测波长为230nm。结果:别嘌醇在21.3~149.1μg·mL-1(进样量20μL)之间,样品浓度与峰面积呈良好的线性关系(r= 0.9999),平均回收率为100.7%,RSD为0.84%。结论:本法结果准确,精密度及重现性较好,可准确控制本品质量。
【Abstract】 Objective:To establish a RP-HPLC method for determination of allopurinol in allo- purinol sodium for injection.Methods:The HPLC was performed on a C18column(250 mm×4.6 mm, 5μm)at 30℃with a flow rate of 1.0 mL·min-1,an eluate consisted of 0.125% potassium dihydrogen phosphate-methanol(95:5)and a detection wavelength at 230 nm.Results:A linearity of allopurinol con- centration was in the range of 21.3~149.1μg·mL-1(r=0.9999).The average recovery was 100.7% , and the RSD was 0.84%.Conclusion:This reliable and reproducible RP-HPLC method is applied in the quality control of allopurinol in allopurinol sodium for injection.
- 【文献出处】 中国新药杂志 ,Chinese Journal of New Drugs , 编辑部邮箱 ,2006年13期
- 【分类号】R927
- 【被引频次】3
- 【下载频次】87