节点文献

全钒液流电池高浓度下V(IV)/V(V)的电极过程研究

Investigations on the Electrode Process of Concentrated V(IV)/V(V) Species in a Vanadium Redox Flow Battery

  • 推荐 CAJ下载
  • PDF下载
  • 不支持迅雷等下载工具,请取消加速工具后下载。

【作者】 文越华张华民钱鹏赵平周汉涛衣宝廉

【Author】 WEN, Yue-Hua1, 2 ZHANG, Hua-Min1* QIAN, Peng1 ZHAO, Ping1 ZHOU, Han-Tao1 YI, Bao-Lian1(1 Full Cell R&D Center, Dalian Institute of Chemical Physics, Chinese Academy of Sciences, Dalian 116023, P. R. China;2 Chemical Defence Institute, Beijing 100083, P. R. China)

【机构】 中国科学院大连化学物理研究所 燃料电池工程中心中国科学院大连化学物理研究所燃料电池工程中心辽宁大连116023北京防化研究院军用电源发展与研究中心北京100083辽宁大连116023

【摘要】 采用循环伏安、低速线性扫描和阻抗技术,以石墨为电极,研究了V(IV)/V(V)在较高浓度下的电极过程.结果表明,采用2.0mol·L-1的V(IV)溶液时,H2SO4浓度低于2mol·L-1,V(IV)/V(V)反应极化大,可逆性差,表现为电化学和扩散混合控制;H2SO4浓度增至2mol·L-1以上,V(IV)/V(V)反应的可逆性提高,转为扩散控制,且增加H2SO4浓度有利于阻抗的降低;但H2SO4浓度超过3mol·L-1,溶液的粘度和传质阻力大,阻抗反而增大.在3mol·L-1的H2SO4中,随着V(IV)浓度的增加,体系的可逆性和动力学改善,阻抗减小;但V(IV)浓度超过2.0mol·L-1,较高的溶液粘度导致溶液的传质阻力迅速增加,V(IV)/V(V)的电化学性能衰减,阻抗增大.因此,综合考虑电极反应动力学和电池的能量密度两因素,V(IV)溶液的最佳浓度为1.5~2.0mol·L-1,H2SO4浓度为3mol·L-1.

【Abstract】 The electrode process of concentrated V(IV)/V(V) species has been studied at a graphite electrode using cyclic voltammetry, linear polarization, and impedance techniques. The results have revealed that in H2SO4 solution below 2 mol·L-1 containing 2.0 mol·L-1 V(IV), the electrode process of V(IV)/V(V) is controlled by the electrochemical polarization and diffusion with poor reversibility. When the concentration of H2SO4 is above 2 mol·L-1, the electrode process of V(IV)/V(V) turns into the diffusion control with improvement of the reversibility. An increase in concentration of H2SO4 solution facilitates a decrease in impedance, whereas too high concentration of H2SO4 solution( > 3 mol·L-1) results in a remarkable increase in the viscosity of solution leading to a large mass transportation polarization, and thus the impedance starts to increase a bit. In 3 mol·L-1 H2SO4 solution, the reversibility and kinetics of V(IV)/V(V) are improved gradually as well as the characteristics of impedance with increasing concentration of V(IV) solution. But,when the concentration of V(IV) solution exceeds 2.0 mol·L-1, the viscosity of the solution is so high that the mass transportation polarization increases considerably, resulting in the deterioration of electrochemical performance of V(IV)/V(V) species and an increase in impedance. Therefore, considering from standpoint of increasing the energy density and electrode kinetics comprehensively, the optimal concentration of H2SO4 is 3 mol·L-1 containing 1.5~2.0 mol·L-1 of V(IV).

【基金】 国家高技术研究发展计划(2005AA516020)资助项目
  • 【文献出处】 物理化学学报 ,Acta Physico-Chimica Sinica , 编辑部邮箱 ,2006年04期
  • 【分类号】O646.54
  • 【被引频次】83
  • 【下载频次】878
节点文献中: