节点文献

电动自行车用铅蓄电池组的过放电

Over-discharge of VRLA battery for electric bicycle

  • 推荐 CAJ下载
  • PDF下载
  • 不支持迅雷等下载工具,请取消加速工具后下载。

【作者】 桂长清郭莉

【Author】 GUI Chang-qing~1,GUO Li~2(1.CSSC 712 Research Institute,Wuhan,Hubei 430064,China;2.China Commercial Group General Electronic Co.,Ltd.,Foshan,Guangdong 528000,China)

【机构】 中船总公司712研究所中国商通电子有限公司 湖北武汉430064广东佛山528000

【摘要】 电动自行车用密封铅蓄电池5 A恒电流放电至终止电压10.5 V,静置0.5 h,电池组电压出现回升,仍可继续放电。如此过放电数次,总计可使电池容量增加10%~19%。其总放电量相当于电池长时率放电容量。这种过放电可加剧板栅腐蚀,在板栅/活性物质界面产生高电阻层,并引起正极活性物质软化脱落,使电池放电容量迅速下降,促使电池早期失效。

【Abstract】 A VRLA battery group used for electric bicycle was discharged at constant current of 5 A to the final discharge voltage,and then left standing open-circuited for half an hour.After this its open-citcuit voltage increased gradually,and it might be discharged again,which made the battery capacity increase about 10 %~19 %,and the total discharging capacity was about equal to the capacity being discharged at low discharge rate.Suchlike over-discharge resulted in accelerated corrosion of grids,forming a high resistance barrier on the interface between the grid/positive active material,softening and shedding of positive active material and fast reducing the discharge capacity,as a result,the battery suffered from premature capacity loss.

【关键词】 铅蓄电池电动车过放电失效
【Key words】 lead-acid batteryEVover-dischargefailure
  • 【文献出处】 蓄电池 ,Chinese Labat Man , 编辑部邮箱 ,2006年02期
  • 【分类号】TM912
  • 【下载频次】143
节点文献中: