节点文献

全身麻醉药对短潜伏期体感诱发电位的影响

Effects of intravenous and inhalational anesthetics on short-latency somatosensory evoked potentials

  • 推荐 CAJ下载
  • PDF下载
  • 不支持迅雷等下载工具,请取消加速工具后下载。

【作者】 梁伟民张军顾华华唐俊黄奇志

【Author】 LIANG Wei-min, ZHANG Jun, GU Hua-hua, TANG Jun, HUANG Qi-zhi. Deportment of Anesthesia, Huashan Hospital, Fudan University, Shanghai 200040, China

【机构】 复旦大学华山医院麻醉科复旦大学华山医院麻醉科 200040上海200040上海

【摘要】 目的 为术中进行体感诱发电位监测选择合适的全身麻醉药及剂量。方法 将 15 0例神经外科择期手术病人利用随机排列表分成静脉组和吸入组。静脉组 90例 ,分为异丙酚 (1 5mg/kg、2mg/kg、3mg/kg)、咪哒唑仑 (0 2mg/kg、0 3mg/kg、0 4mg/kg)和依托咪酯 (0 15mg/kg、0 3mg/kg、0 4mg/kg) 9个组 ,每组 10例 ,观察用药后对短潜伏期体感诱发电位 (shortlatencysomatosensoryevokedpotential,SLSEP)的影响 ;吸入组 6 0例 ,分为安氟醚、异氟醚和地氟醚组 ,每组 2 0例 ,按呼气末浓度 0 3、0 5、0 75、1 0和 1 5最低肺泡有效浓度 (MAC)进行观察。观察指标为N14 、N2 0 和中枢传导时间 (CCT)。结果 静脉药中异丙酚能明显抑制N2 0 波幅 ,但N14 、N2 0 的潜伏期和CCT的影响不明显 ,咪哒唑仑抑制N2 0 波幅 ,延长N2 0 的潜伏期和CCT ,依托咪酯明显增大N2 0 波幅 ,且病人已清醒睁眼时该作用仍未消退。吸入药均表现出对N2 0 和CCT的影响 ,安氟醚在 1 0MAC时出现波形消失 ,而异氟醚和地氟醚则在 1 5MAC才出现该现象。结论 在全身麻醉病人进行SLSEP监测时 ,全麻诱导时可选择依托咪酯 ,在全麻维持阶段 ,吸入麻醉药可选择异氟醚或地氟醚 ,浓度应控制在 1 0MAC以下。

【Abstract】 Objective To choose suitable general anesthetics dosages when short-latency somatosensory evoked potentials (SLSEP) is monitored during operation. Methods 150 ASA I-II neurosurgical patients undergoing elective operations were randomly divided into intravenous anesthesia group of 90 patients and inhalation anesthesia group 0f 60 patients. The intravenous anesthesia group was further divided into 9 subgroups of 10 patients treated with different anesthetics of different dosages: propofol (1.5 mg/kg, 2 mg/kg, and 3 mg/kg), midazolam (0.2 mg/kg, 0.3 mg/kg, and 0.4 mg/kg), and etomidate (0.15 mg/kg, 0.3 mg/kg, and 0.4 mg/kg). The intravenous anesthetics were given and upper limb SLSEP was monitored continuously. The inhalation anesthesia group was further divided into enflurane, isoflurane and desflurane subgroups of 20 patients each. The inhalational anesthetics were given at the concentrations corresponding to the end-expiratory concentrations of 0 to 0.3, 0.5, 0.75, 1.0 and 1.5 MAC. The changes of N14, N20 and central conduction time (CCT) were recorded. In addition to SLSEP, EKG, NIBP, SpO2, PETCO2 were monitored as well as end-tidal anesthetic concentration. During the experiment SpO2 was maintained > 95 % and PETCO2 was maintained at the range of 35~45 mmHg by mask oxygen or assisted ventilation. Results The intravenous anesthetic propofol significantly decreased N20 amplitude and produced less effect on the latency of N14, N20 and CCT. Midazolam significantly decreased the N20 amplitude and prolonged the latency of N20 and CCT. Etomidate significantly increased the N20 amplitude, and the change did not recover when the patients had opened their eyes 10 minutes after medication. All three inhalational anesthetics significantly decreased the N20 amplitude and prolonged the N20 latency and CCT. N20 amplitude disappeared in some patients treated with enflurane when the end-expiratory concentration was 1.0 MAC, while disappeared in some patients treated with isoflurane and desflurane when the end-expiratory concentration was 1.5 MAC for these 2 drugs. Conclusion When using SLSEP monitoring, the most suitable general anesthetic is etomidate during the induction stage and isoflurane and desflurane during the maintenance stage with the end-expiratory concentration below 1.0 MAC.

  • 【文献出处】 中华医学杂志 ,National Medical Journal of China , 编辑部邮箱 ,2004年06期
  • 【分类号】R614
  • 【被引频次】17
  • 【下载频次】138
节点文献中: