固有括约肌功能障碍型女性压力性尿失禁的尿动力学诊断
Urodynamic evaluation of female stress urinary incontinence due to intrinsic sphincter deficiency
【摘要】 目的 探讨尿动力学诊断固有括约肌功能障碍型 (ISD)女性压力性尿失禁的临床价值。 方法 30例患者中Ⅲ型 11例 ,Ⅱ /Ⅲ型 (解剖和ISD混合型 ) 19例 ,分别行漏尿点测压 (LPP)和最大尿道关闭压 (MUCP)测定 ,比较分析各组数据。 结果 Ⅲ型患者中LPP <5 0cmH2 O 10例 ,Ⅱ /Ⅲ型患者中LPP 5 0~ 10 0cmH2 O 17例 ,两组LPP值差异有显著性意义 (P <0 .0 1) ;而MUCP值的分布无特异性 ,两组间差异无显著性意义 (P =0 .5 5 )。 结论 LPP值测定对于诊断ISD及尿失禁的分型有重要意义。
【Abstract】 Objective To evaluate urodynamic diagnosis of intrinsic sphincter deficiency (ISD) in female stress urinary incontinence. Methods Leak-point pressures (LPP) and maximum urethra close pressures (MUCP) were detected in 30 patients with female stress urinary incontinence,among whom there were 11 cases with type Ⅲ,19 type Ⅱ/Ⅲ. Results Of type Ⅲ incontinence the LPP was less than 50 cmH 2O in 10 out of 11 and in 17 out of 19 type Ⅱ/Ⅲ incontinence the LPP 50~100 cmH 2O ( P <0.01).There was no significant difference between the MUCP of the two groups. Conclusions LPP determination is important in the assessment of intrinsic sphincter deficiency.
- 【文献出处】 中华泌尿外科杂志 ,Chinese Journal of Urology , 编辑部邮箱 ,2003年06期
- 【分类号】R695
- 【被引频次】7
- 【下载频次】123