节点文献
Treatment of spent caustic by three kinds of photocatalyticoxidation processes
【Abstract】 The investigation of the performance of UV/H2O2, UV/O3 and UV/H2O2/O3 oxidation systems treating spent caustic from an ethylene plant shows that in UV/H2O2 system, with the increase of H2O2dosage, removal efficiencies of COD and the ratio of biochemical oxygen demand (BOD) to chemical oxygen demand (COD) of the effluent were increased and a better performance was obtained than the H2O2system alone. In UV/H2O2 system, removal efficiency of COD reached 68% under the optimum condition, and BOD/COD ratio was significantly increased from 0.22 to 0.52. In UV/O3 system, with the increase of O3dosage, removal efficiency of COD and BOD/COD ratio were increased, and a better performance was obtained than the O3system alone. Under the optimum condition, removal efficiency of COD was 54%, and BOD/COD ratio was significantly increased from 0.22 to 0.48. In UV/H2O2/O3 system, COD removal efficiency was found to be 22.0% higher than UV/O3 system.
- 【文献出处】 Journal of Harbin Institute of Technology ,哈尔滨工业大学学报(英文版) , 编辑部邮箱 ,2003年04期
- 【分类号】X703
- 【被引频次】3
- 【下载频次】22