应变靶式流量计的误差分析与对策

The Analysis on Error of Strain Target Flowmeter and the Countermeasures

  • 推荐 CAJ下载
  • PDF下载
  • 不支持迅雷等下载工具,请取消加速工具后下载。

【摘要】 靶式流量计测量高粘度介质流量有其独特的优点。传统的靶式流量计存在机械结构复杂、灵敏度低、量程范围窄等缺点。本文介绍的新型应变靶式流量计采用了专利技术 ,结构简单、灵敏度高 ;另外在软、硬件上实时地对测量结果进行修正 ,从而大大提高了测量精度和测量范围。

【Abstract】 Target flowmeters offer unique features to flow measurement of media with high viscosity.While the traditional target flowmeter is complicated in mechanical structure and features low sensitivity and narrow range. The new strain target flowmeter introduced in this paper is adopting patented technology, offers simple structure and high sensitivity. In addition, the result of measurement is corrected in real time by software and hardware. Thus it highly enhanced measuring accuracy and range.

【关键词】 靶式流量计误差补偿
【Key words】 Target flowmeter Error Compensation
  • 【文献出处】 自动化仪表 ,Process Automation Instrumentation , 编辑部邮箱 ,2002年06期
  • 【分类号】TH814
  • 【被引频次】23
  • 【下载频次】201