节点文献

微富集柱-FAAS联用测定铅的影响因素分析

Influential Factors in Determination of Lead by FAAS with Micro-column Preconcentration

  • 推荐 CAJ下载
  • PDF下载
  • 不支持迅雷等下载工具,请取消加速工具后下载。

【作者】 刘文涵高云芳黄荣斌赵锋赵力达周执明

【Author】 LIU Wen- han, GAO Yun- fang, HUANG Rong- bin, ZHAO Feng, ZHAO Li- da, ZHOU Zhi- ming(College of Chemical Engineering, Zhejiang University of Technology, Hangzhou 310032, China)

【机构】 浙江工业大学化工学院浙江工业大学化工学院 浙江杭州310032浙江杭州310032浙江杭州310032

【摘要】 研究了微富集柱与原子吸收光谱法联用测定铅的各种影响因素,实验利用自制的微型电化学富集柱对金属离子的吸附效应进行预富集 ,再瞬间溶出直接进入原子吸收进行测定 ,极大地提高了测试灵敏度和降低了检出限 ,可使铅测定中的特征浓度和检出限降低1~2个数量级

【Abstract】 Influential factors in determination of lead have been studied by combination of FAAS with micro- cell preconcentration. A self- made electrochemical preconcentration micro- cell was used to adsorb lead ion in sample for its enrichement. Then the adsorbed ions were instantly stripped in small size and directly introduced into a flame atomizer of FAAS. Under the selected conditions this method can greatly improve sensitivity of detection of lead. The characteristic concentration and detection limit for the determination of lead can be improved with 1~2 orders of magnitude.

【基金】 浙江省分析测试基金资助项目 (97044)
  • 【文献出处】 分析测试学报 ,Journal of Instrumental Analysis , 编辑部邮箱 ,2002年04期
  • 【分类号】O657.3
  • 【被引频次】7
  • 【下载频次】55