【摘要】 设计了两种适用于光波导高精度对接耦合的自动调芯方案 ,这两种方案从原理上克服了常规调芯过程依赖于对微变信号精确测试的困难。提出了实现自动调芯的结构 ,完成了调芯系统的光机电一体化、相应的控制程序以及与计算机的接口界面。采用通信用单模光纤作为标准光波导做了端面耦合试验 ,自动调芯结果显示 ,在 1310nm波长上 ,平均耦合损耗为 0 .0 75dB ,标准误差为 0 .0 0 99dB ;在 15 5 0nm波长上 ,平均耦合损耗为 0 .0 6 2dB ,标准误差为 0 .0 0 6 6dB。自动调芯过程在 2min内完成。
【Abstract】 The auto-aligning projects and the corresponding programs are designed. The primary optical-electromechanical integration and the interfaces with computer are accomplished. The auto-aligning experiment using single mode fiber for the communication as a standard waveguide was carried out. The results show that the average end-coupling loss and the standard deviation are 0.075 dB and 0.009 9 dB at wavelength of 1 310 nm, and 0.062 dB and 0.006 6 dB at 1 550 nm respectively. It takes less than 2 minutes to finish the whole auto-aligning process.
【Key words】 waveguide; fiber; end-coupling; coupling-loss; auto-aligning;