节点文献
机械可脱式弹簧圈栓塞治疗颅内动脉瘤的评价
Evaluation to Treatment of Intracranial Aneurysm with Mechanical Detachable Spiral
【摘要】 目的 :评价机械可脱式弹簧圈 (MechanicalDetachableSpiral,MDS)栓塞治疗颅内动脉瘤。方法 :对 1995年 3月~ 1998年 7月利用MDS栓塞的 64例 66个颅内动脉瘤进行回顾性分析。结果 :66个动脉瘤中 ,10 0 %栓塞的 2 5个 ,占 3 7 9% (2 5 /66) ;95 %的 19个 ,占 2 8 8% ;90 %的 11个 ,占 16 7% ;80 %的 6个 ,占 9 1% ;<80 %的 5个 ,占 7 6%。 5 5个 (83 3 % )动脉瘤达 90 %以上栓塞。死亡 2例 (3 1% ) ,永久并发症 3例 (4 7% )。结论 :应用MDS进行囊内栓塞 ,是治疗颅内动脉瘤安全有效的方法之一
【Abstract】 Aim:To evaluate the embolization treatment of intracranial aneurysms with mechanical detachable spiral (MDS). Methods:Sixty four intracranial aneurysm patients with 66 aneurysms,which were intrasaccularly embolized with MDS from March 1995 to July 1998, were analysed retrospectively.Results:Among 66 aneurysms, 100% occlusion was reached in 25 (37 9%, 25/66), 95% in 19 (28 8%), 90% in 11 (16 7%), 80% in 6 (9 1%) and less than 80% in 5 (7 6%) respectively, with mortality of 3 1% (2/64) and permanent mobidity of 4 7% (3/60). Conclusion:Embolization with MDS is one of the choices of the safe and effective treatments to intracranial aneurysms.
【Key words】 intracranial aneurysm therapeutic embolization mechanical detachable spiral(MDS);
- 【文献出处】 中国临床神经科学 ,Chinese Journal of Clinical Neurosciences , 编辑部邮箱 ,2001年02期
- 【分类号】R743.4
- 【被引频次】3
- 【下载频次】48