PVC-丁二酮肟膜修饰玻碳电极及其在钯的分析中的应用
PVC dimethylglyoxime modified glass carbon electrode and its application in analysis of palladium
【摘要】 制备了 PVC-丁二酮肟修饰电极 ,研究了膜电极的响应过程和钯在此电极表面的伏安特性。用微分脉冲伏安法测定 ,钯在 4.76× 1 0 -9mol/ L~ 9.53×1 0 -8mol/ L 的浓度范围内 ,电流与浓度的对数成线性关系 ,检出限为 1 .52×1 0 -9mol/ L。此法可用于矿样中钯的测定。
【Abstract】 A PVC dimethylglyoxime coated glass carbon electrode was prepared. The differential pulse voltammetry (DPV) of Pd(Ⅱ) on the electrode was studied.A linear calibration graph was obtained in the range of 4.76×10 -9 ~9.53×10 -8 mol/L with detection limit of 1.52×10 -9 mol/L for Pd(Ⅱ). The method was applied to the determination of palladium in minerals.
【关键词】 化学修饰电极;
微分脉冲伏安法;
钯;
【Key words】 Chemically modified electrode; Differential pulse voltammetry; Palladium;