【摘要】 通过分析消弧线圈在运行中的动作机理 ,结合 KD- XH消弧系统所提供的现场运行数据 ,论述了可控消弧系统为确保其良好的应用效果而应具备的主要性能 ,即必须具有线性良好的伏安特性、足够快的响应速度、对配电网当前状态和长远发展的良好适应性 ,并强调了在目前可控消弧系统尚无标准可循的情况下 ,也必须充分重视这些重要的性能要求。
【Abstract】 Through the analysis on the response mechanism of arc suppression coil and based on the information derived from the records of the on site KD XH compensation systems, it is pointed out in this paper that to ensure its applied effect the controllable arc suppression system should possess following main performances: linear volt ampere characteristic curve, high response speed and good adaptability to present situation and future development of distribution network. It is also emphasized that under the present situation that there is no standard for controllable arc suppression system special attention should be paid to these important performances.
【Key words】 distribution network; arc suppressing coil; neutral point; grounding way; volt ampere characteristics, response speed.;