500kV线路绝缘子串分布电压的现场实测与分析
Field Measurement and Analysis of Voltage Distribution on 500 kV Transmission Line Insulator Strings
【摘要】 介绍广州地区500kV线路绝缘子串分布电压的现场实测,通过分析,得出如下规律:无论单串或双串,中相绝缘子串的电压分布总比边相串更不均匀;在相同条件下,绝缘子串的元件数越多,电压分布越不均匀;中相V型串与垂直串的电压分布规律非常接近;酒杯塔与拉V塔的塔型对边相绝缘子串的电压分布规律无明显影响。
【Abstract】 The paper describes the field measurement of voltage distribution on insulator strings on insulator strings on 500 kV transmission lines in Guangzhou area. By analysis, the regularities were obtained as follows: the voltage distribution on insulator string of the middle-phase, whether single or double strings are more uniform than that of side-phase under the same conditions, the more units of insulator strings the more uniform of voltage distribution on middle-phase. The regularity of voltage distribution are very similar between V-sin fig and vertical string. On side-phases, the voltage distribution of insulator string is not affected significantly by tower types.
- 【文献出处】 中国电力 ,ELECTRIC POWER , 编辑部邮箱 ,2000年02期
- 【分类号】TM726
- 【被引频次】61
- 【下载频次】374