节点文献
湘钢3号高炉更换大钟的实践
Replacement of large bell of No.3 BF at Xiangtan Steel
【摘要】 湘钢3号高炉(1000m~3)由于大钟上与大钟漏斗接触的密封面严重磨损,炉顶煤气泄漏严重,高炉生产无法正常进行。在高炉无法进行中修的情况下,通过采用新型的平移拆装方式对大钟进行了更换,从而保证了高炉的正常生产。
【Abstract】 The seal face on the large bell of No. 3 BF (1 000 m3) at Xiangtan Steel was worn by burden and gas,the top gas leakage occurred frequently,and the normal production of BF was disrupted. In order to keep the BF production , a new method replacing large bell was adopted. As a result,the worn large bell was replaced successfully.
- 【文献出处】 炼铁 ,Iron Making , 编辑部邮箱 ,2000年03期
- 【分类号】TF548
- 【下载频次】29