节点文献
破伤风抗毒素试验液配制的探讨
Exploration of Oplimum Concentration of Tetanus Antitoxin Skin Test Solution
【摘要】 目的 降低破伤风抗毒素皮试液在临床应用中的假阳性率,提高应用破伤风抗毒素的准确性;方法 采用武汉生物研究所生产的破伤风抗毒素(TAT) 剂量1500U/支,分别用生理盐水配制成75U/ml、15U/ml、150 U/ml 三种不同浓度,分两组对比研究,其结果经统计学处理;结果 破伤风抗毒素150U/ml 假阳性最高,75U/ml 次之,15U/ml 无假阳性,也无假阴性;结论 通过对比认为15U/ml 的破伤风抗毒素皮试液为最佳皮试液。
【Abstract】 Objective To lower false-positive rate of tetanus antitoxin skin test solution and raise accuracy of tetanus antitoxin in clinical practice. Methods To dilute tetanus antitoxin with normal saline into three different concentrations:75u/ml,15u/ml and 150u/ml respectively.Results False-positive rate of the 150u/ml was the highest,the second was 75u/ml and that concentration of 15u/ml was without false-positive and false-negative.Conclusion Tetanus antitoxin skin test solution with concentration of 15u/ml is optimus.
- 【文献出处】 菏泽医专学报 ,Journal of Heze Medical College , 编辑部邮箱 ,1999年02期
- 【分类号】R472
- 【下载频次】16