【摘要】 简单介绍了成庄电厂的锅炉设备,分析了在高负荷时主汽温度变化剧烈的原因,提出了改进措施,改进后的效果,供以后锅炉设计时参考。
【Abstract】 This paper briefly introduces boiler equipment in Chengzhuang PowerPlant, analyzes reasons for rapid variations of main steam temperature under heavyload, proposes improveing measures and gives improvement results for reference in thefuture boiler design.