节点文献

X射线胶片的脉冲光源响应标定

Response Calibration of X-Ray Film to a Pulse X-Ray Source

  • 推荐 CAJ下载
  • PDF下载
  • 不支持迅雷等下载工具,请取消加速工具后下载。

【作者】 何绍堂黄文忠孙永良易荣清周裕清何安杜凤英洪伟

【Author】 He Shaotang, Huang Wenzhong, Sun Yongliang, Yi Rongqing,Zhou Yuqing, He An, Du Fengying, Hong Wei(Southwest Institute of Nuclear Physics and Chemistry, Chengdu 610003)

【机构】 西南核物理与化学研究所

【摘要】 用LF-11激光装置的1.06μm脉冲激光加热Cu靶产生的L-壳层线辐射作脉冲X射线源,在曝光量为(0.01~10)-7J·cm-2范围内,标定了KODAKAA-5,KODAKSWR和UFSH-O软X射线胶片的响应曲线,并与用连续光源标定的进行了对比.结果表明,这三种x射线胶片,在强脉冲光源曝光条件下,都存在着胶片响应互易律失效问题,过去用连续光源标定的响应曲线,在激光等离子体诊断实验中,已经不能采用.

【Abstract】 By using the strong L-lines emitted from Cu plasma as pulse X-ray source produced by irradiating Cu target with a 1. 06 μm pulse laser of the LF-11 laser facility,the reponses of X-ray film Kodak AA-5, Kodak SWR and UFSH-O were calibrated.Calibrated responses with the pulse X-ray source were compared with that with continuum X-ray source (fluoresent source exciteed by protons ). These results showed the reciprocity failure. The response to continuum X-ray source is not suitable for the diagnostics in laser-induced plasma.

【基金】 中国工程物理研究院科学基金
  • 【文献出处】 光学学报 ,ACTA OPTICA SINICA , 编辑部邮箱 ,1994年12期
  • 【分类号】TQ577.25
  • 【被引频次】1
  • 【下载频次】30
节点文献中: