节点文献

4πγ电离室活度测量标准装置

A 4πγ IONIZATION CHAMBER SUBSTANDARD FOR ACTIVITY MEASUREMENTS

  • 推荐 CAJ下载
  • PDF下载
  • 不支持迅雷等下载工具,请取消加速工具后下载。

【作者】 陈宝林; 周维妕; 谭永康; 朱黎明; 唐方东;

【Author】 CHEN BAOLIN;ZHOU WEIZHONG;TAN YONGKANG;ZHU LIMING;TANG FANGDONG Shanghai Institute of Metrology

【机构】 上海市计量技术研究所; 上海市计量技术研究所;

【摘要】 文章叙述了所建立的4πγ电离室活度测量标准装置的结构和性能。说明了用125I作为探针,对源瓶子进行筛选的必要性。电离室共刻度了26个核素,刻度的总不确定度(3σ)在1.2%-4.6%。导出了一条完整的4πγ电离室效率曲线,可用来预言未作过刻度的核素的刻度值。

【Abstract】 The structure and performance of the 4 πγ ionization chamber substandardestablished are described. The necessity of selecting source vials in accordance withwall absorption fractions using a 125I needle source which is used as asensitiveprobe is stated. The chamber is calibrated with 26 radionuclides. Theoverall uncertainties (3 σ) of calibration factors are in range of 1.2--4.6%.A efficiency curve of the chamber is derived and it can be used to predict thecalibration factors of those radionuclides for which the chamber isn’t calibrated.

  • 【文献出处】 原子能科学技术 ,Atomic Energy Science and Technology , 编辑部邮箱 ,1991年01期
  • 【被引频次】3
  • 【下载频次】54