With finite-element analogue, the thesis analyses the performance of the protective structure on resisting blasting load in turn when effected by load in different direction or covered by different soil cover or with energy-dissipating layers of different size.
Though the study on the five different loads,it can be concluded that the protective structure has enough bearing capacity when blasting load affecting on different position of the structure, and the center of the top of the earth is leas...