Evaluation of TiAl and 40Cr diffusion bonding quality using ultrasonic reflection spectrum

  • 推荐 CAJ下载
  • PDF下载
  • 不支持迅雷等下载工具,请取消加速工具后下载。

【作者】 栾亦琳刚铁

【Author】 Luan Yilin and Gang TieLuan Yilin and Gang Tie, State Key Laboratory of Advanced Welding Production Technology, Harbin Institute of Technology, Harbin, 150001.

【机构】 State Key Laboratory of Advanced Welding Production Technology Harbin Institute of TechnologyState Key Laboratory of Advanced Welding Production TechnologyHarbin Institute of TechnologyHarbin 150001

【摘要】 Combined with ultrasonic pulse-echo technique, reflection spectrum analysis was introduced to evaluate TiAl and 40Cr diffusion bonding quality. Frequency dependence of reflection coefficient was used to distinguish perfect bonding from imperfect bonding. It is found that the reflection coefficient from perfect bonding interface does not vary with frequency. When the size of imperfections is much smaller than the wavelength of ultrasound, the reflection coefficient depends on frequency. When the size of imperfections is the same order of or even larger than the wavelength of ultrasound, the reflection coefficient does not exhibit frequency dependence. However the amplitude of imperfect interface is higher than the amplitude of perfect bonding interface. A combination of reflection spectrum analysis and ultrasonic pulse-echo technique provides more accurate information about the bonding quality of dissimilar materials.

【Abstract】 Combined with ultrasonic pulse-echo technique, reflection spectrum analysis was introduced to evaluate TiAl and 40Cr diffusion bonding quality. Frequency dependence of reflection coefficient was used to distinguish perfect bonding from imperfect bonding. It is found that the reflection coefficient from perfect bonding interface does not vary with frequency. When the size of imperfections is much smaller than the wavelength of ultrasound, the reflection coefficient depends on frequency. When the size of imperfections is the same order of or even larger than the wavelength of ultrasound, the reflection coefficient does not exhibit frequency dependence. However the amplitude of imperfect interface is higher than the amplitude of perfect bonding interface. A combination of reflection spectrum analysis and ultrasonic pulse-echo technique provides more accurate information about the bonding quality of dissimilar materials.

  • 【文献出处】 China Welding ,中国焊接(英文版) , 编辑部邮箱 ,2007年02期
  • 【分类号】TG441.7
  • 【被引频次】4
  • 【下载频次】75
节点文献中: 

本文链接的文献网络图示:

本文的引文网络