节点文献

波槽管管外PTFE涂层滴状冷凝换热实验研究

An experimental study of steam drop-wise condensation on the FTFE film outside circularly groove tube

  • 推荐 CAJ下载
  • PDF下载
  • 不支持迅雷等下载工具,请取消加速工具后下载。

【作者】 胡友森黄渭堂隋海明

【Author】 HU You-sen,HUANG Wei-tang,SUI Hai-ming(College of Power and Energy Engineering,Harbin Engineering University,Harbin 150001,China)

【机构】 哈尔滨工程大学动力与能源工程学院哈尔滨工程大学动力与能源工程学院 黑龙江哈尔滨150001黑龙江哈尔滨150001

【摘要】 波槽管是近期开发的一种强化管.为获得更好的传热效果,在波槽管管外敷设了聚四氟乙烯(PTFE)涂层,以得到滴状冷凝来改善管外换热状况.介绍了普通光管、波槽管、25μm涂层圆管、25μm和8μm涂层波槽管的凝结换热实验结果,并对其进行了分析.涂层圆管和涂层波槽管表面均得到了持续、良好的滴状冷凝,8μm涂层波槽管在略高于大气压的蒸汽环境中获得了最大的传热系数.

【Abstract】 The circularly groove tube is one kind of strengthened tube developed recently.In order to obtain the higher heat transfer coefficient,PTFE coat is laid outside of circularly grooved tube to obtain the drop-wise condensation to improve the heat transfer condition outside the tube.In this paper, various heat transfer experimental results are demonstrated for ordinary tube,circularly grooved tube,25 μm coating circular tube,25 μm and 8 μm coating circularly-grooved tubes.The results are made an analysis.For coated circular tube and circularly-grooved tube,the good drop-wise condensation is achieved on the surface,while 8 μm coating circularly-grooved tube obtains maximum beat transfer coefficient under the vapor pressure a little higher than atomspheric pressure.

【关键词】 波槽管聚四氟乙烯滴状冷凝
【Key words】 circularly groove tubePTFEdrop-wise condensation
  • 【文献出处】 应用科技 ,Applied Science and Technology , 编辑部邮箱 ,2007年05期
  • 【分类号】TK124
  • 【被引频次】12
  • 【下载频次】155