节点文献
200MW非再热双抽供热机组变工况计算及工况图的绘制
Different Operational Conditions Calculation & Drawing the Working Conditions for 200MW Non-Reheat Double-Extraction Thermal Power Plant Unit
【摘要】 工况图在热电厂的设计和运行中具有广泛的用途,本文根据引进型双抽非再热200MW供热机组的技术特点,通过编程在纯凝汽工况、单抽工业抽汽工况、单抽采暖抽汽工况和双抽供热等典型变工况计算的基础上,完成了当新蒸汽负荷、工业抽汽负荷和采暖抽汽负荷发生改变时的变工况计算,并绘制了该机组的运行工况图.
【Abstract】 Operating Condition Chart has a wide use in design and operation of thermal plant.According to the traits of imported 200MW double-extraction thermal power plant unit,the thermal balance calculations of this unit in fiducial or varying operating conditions are made by the varying operating condition calculation programs,and an OCC(Operating Condition Chart) of this plant is obtained based on these calculations and then contrasted with the OCC of homemade plants.
【关键词】 非再热;
供热机组;
变工况计算;
工况图绘制;
【Key words】 non-reheat; thermal power plant unit; different operational conditions calculation; drawing the working conditions;
【Key words】 non-reheat; thermal power plant unit; different operational conditions calculation; drawing the working conditions;
- 【文献出处】 新疆大学学报(自然科学版) ,Journal of Xinjiang University(Natural Science Edition) , 编辑部邮箱 ,2007年02期
- 【分类号】TM621.4
- 【被引频次】8
- 【下载频次】351