【作者】 李文龙陈军辉韩超王小如

【Author】 LI Wen-long1,CHEN Jun-hui1,2,HAN Chao3,WANG Xiao-ru1,31Qingdao Key Laboratory of Analytical Technology Development and Standardization of Chinese Medicines, First Institute Oceanography of SOA,Qingdao 266061,China;2College of Chemistry and Chemical Engineering,Ocean University of China,Qingdao 266006,China;3Department of Chemistry and the Key Laboratory of Analytical Science of the MOE,College of Chemistry and Chemical Engineering,Xiamen University,Xiamen 361005,China

【机构】 国家海洋局第一海洋研究所现代分析技术及中药标准化重点实验室厦门大学化学化工学院化学系现代分析科学教育部重点实验室国家海洋局第一海洋研究所现代分析技术及中药标准化重点实验室 青岛266061青岛266061中国海洋大学化学化工学院青岛266003厦门361005

【摘要】 建立了测定太子参中环肽Pseudostellarin B含量的高效毛细管电泳(HPCE)分析方法,对10种不同产地太子参中环肽Pseudostellarin B的含量进行了测定。HPCE工作条件:采用未涂层熔融石英毛细管(内径75μm,有效长度50cm),分离电压为15kV,柱温20℃,二极管阵列检测器(DAD)检测波长为203nm,缓冲液为20mmol/L硼砂(pH=9.3)溶液。在选定的工作条件下,环肽Pseudostellarin B浓度与其响应信号值之间具有较好的线性相关性(Y=0.6357X+2.546,R=0.9985),加标回收率在93.8%~105.6%之间。在此基础上进行了太子参HPCE指纹图谱研究,采用中药指纹图谱相似度计算软件对不同太子参样品的HPCE指纹图谱进行相似度计算,以系统生成的对照指纹图谱为对照模板,10份样品中有8份的相似度在0.90以上,说明该方法可用于太子参质量控制。

【Abstract】 A modern HPCE analysis method was developed for determinating cyclic peptide Pseudostellarin B in Pseudostellaria heterophylla(Miq.) Pax.Separation and determination were carried out by HPCE under the following conditions: bared fused silica capillary (50 cm×75 μm i.d.),20 mmol/L borate (pH=9.3)as buffer,the run voltage is +15 kV,detection length of UV at 203 nm,and column temperature of 20 ℃.The results indicated that the developed method was simple,accurate and reliable for the determination of Pseudostellarin B with a good linearity(Y=0.6357X+2.546,R=0.9985),and the recovery ranges of 93.8%~105.6%.Based on this method,the HPCE fingerprints of Pseudostellaria heterophylla (Miq.) Pax were established.The fingerprints were compared by the software of the similarity evaluation system for chromatographic fingerprint.The fingerprint congruence coefficients of 8 electropherograms in 10 were above 0.90.The method of HPCE fingerprint is reliable and accurate.

【基金】 国家自然科学基金项目(20235020);国家科技部攻关项目(2003BA759C)
  • 【文献出处】 天然产物研究与开发 ,Natural Product Research and Development , 编辑部邮箱 ,2007年02期
  • 【分类号】R284
  • 【被引频次】20
  • 【下载频次】556
节点文献中: 

本文链接的文献网络图示:

本文的引文网络