节点文献

A Novel Biosensor for the Rapid Determination of Biochemical Oxygen Demand

  • 推荐 CAJ下载
  • PDF下载
  • 不支持迅雷等下载工具,请取消加速工具后下载。

【Author】 JIN-SONG CHEN, LI-SHENG ZHANG, AND JIAN-LONG WANG2 Laboratory of Environmental Technology, INET, Tsinghua University, Beijing 100084, China

【摘要】 Objective To investigate the function of a novel biosensor used for the rapid determination of biochemical oxygen demand (BOD) which is developed by our research group based on suspended immobilized microbial cell system in a completely mixed determining chamber as a substitute of the traditional membrane system. Methods Activated sludge was immobilized by PVA gel and used as a bio-sensing element. The novel biosensor was used to measure the short time BOD value and the conventional cultivation method was used for BOD5 measurement. Results A linear relationship was observed for the difference between the current and the concentration of glucose-glutamic acid (GGA) solution below 200 mg/L with a correlation coefficient of 0.995. The optimal response of the sensor was obtained at pH 7.0 and 30℃. The sensor response was within 15 min and was reproducible within ±5% of the mean in a series of eight samples containing 75 mg/L BOD using standard GGA solution. The novel sensor response was found to be fairly constant over a period of 30 days, with ±5% fluctuations. Conclusion A relatively good agreement is found between BOD estimated by the novel BOD biosensor and that determined by the conventional 5-day BOD method. This novel BOD biosensor has good sensitivity, stability and reproducibility.

【Abstract】 Objective To investigate the function of a novel biosensor used for the rapid determination of biochemical oxygen demand (BOD) which is developed by our research group based on suspended immobilized microbial cell system in a completely mixed determining chamber as a substitute of the traditional membrane system. Methods Activated sludge was immobilized by PVA gel and used as a bio-sensing element. The novel biosensor was used to measure the short time BOD value and the conventional cultivation method was used for BOD5 measurement. Results A linear relationship was observed for the difference between the current and the concentration of glucose-glutamic acid (GGA) solution below 200 mg/L with a correlation coefficient of 0.995. The optimal response of the sensor was obtained at pH 7.0 and 30℃. The sensor response was within 15 min and was reproducible within ±5% of the mean in a series of eight samples containing 75 mg/L BOD using standard GGA solution. The novel sensor response was found to be fairly constant over a period of 30 days, with ±5% fluctuations. Conclusion A relatively good agreement is found between BOD estimated by the novel BOD biosensor and that determined by the conventional 5-day BOD method. This novel BOD biosensor has good sensitivity, stability and reproducibility.

【关键词】 BODBOD biosensorWastewaterWater qualityWater pollution
【Key words】 BODBOD biosensorWastewaterWater qualityWater pollution
【基金】 The project was supported by the National Natural Science Foundation of China (Grant No. 50327802).
  • 【文献出处】 Biomedical and Environmental Sciences ,生物医学与环境科学(英文版) , 编辑部邮箱 ,2007年01期
  • 【分类号】X832
  • 【被引频次】7
  • 【下载频次】122
节点文献中: 

本文链接的文献网络图示:

本文的引文网络