节点文献

A/O/O生物膜反应器处理锦纶废水的影响因素

RESEARCHES ON FACTORS AFFECTING NYLON-6 WASTEWATER TREATMENT IN A/O/O BIOFILM REACTORS

  • 推荐 CAJ下载
  • PDF下载
  • 不支持迅雷等下载工具,请取消加速工具后下载。

【作者】 张曼刘国华杨波陈季华

【Author】 ZHANG Man,LIU Guo-hua,CHEN Ji-hua(School of Environmental Science and Engineering,Donghua University,Shanghai 200051,China)

【机构】 东华大学环境科学与工程学院东华大学环境科学与工程学院 上海200051上海200051

【摘要】 试验采用A/O/O生物膜系统对锦纶废水进行处理,考察了硝化液回流比、水力停留时间、DO和进水COD及TN浓度对系统处理效果的影响。结果表明,当进水COD和TN分别为480~525mg/L和24~26mg/L,硝化液回流比3,单个反应器HRT为3.9h,好氧池I和Ⅱ内DO均为3.0mg/L左右时,系统COD和TN去除率分别达95%和70%,出水氨氮低于1.5mg/L,满足GB8978-96污水综合排放一级标准。

【Abstract】 An A/O/O biofilm process was studied for the treatment of Nylon-6 wastewater,and influence factors like nitrate recirculation ratio,HRT(Hydraulic retention time),DO as well as the influent COD and TN were investigated.Results indicated that when the influent COD and TN were 480~525mg/L and 24~26mg/L respectively,nitrate recirculation ratio was 3,HRT in each reactor was 3.9h,DO in aerobic tank I and Ⅱboth were approximately 3.0mg/L,the removal rates of COD and TN could reach to 95% and 70%.Meanwhile the effluent quality met first class discharge standard specified in GB8978-1996 and the ammonia in effluent was less than 1.5mg/L.

【关键词】 A/O/O工艺生物膜脱氮锦纶废水
【Key words】 A/O/Obiofilm systemnitrogen removalNylon-6 wastewater
【基金】 上海市科委资助项目(042312045)
  • 【文献出处】 水处理技术 ,Technology of Water Treatment , 编辑部邮箱 ,2007年05期
  • 【分类号】X783
  • 【被引频次】2
  • 【下载频次】165
节点文献中: 

本文链接的文献网络图示:

本文的引文网络