节点文献

乌拉山发电厂3号锅炉空气分级燃烧改造及运行试验

RETROFIT FOR AIR STAGED BURNING AND OPERATION TEST OF BOILER NO.3 IN WULASHAN POWER PLANT

  • 推荐 CAJ下载
  • PDF下载
  • 不支持迅雷等下载工具,请取消加速工具后下载。

【作者】 佐双吉

【Author】 ZUO Shuang-ji(Nei Monggol Industrial University,Huhehot 010000,Nei Monggol Region,PRC)

【机构】 内蒙古工业大学 内蒙古呼和浩特010080

【摘要】 采用降低总过量空气系数、增加燃尽风(分级二次风)份额和动压头、适当增加含粉三次风等方法,实现了乌拉山发电厂3号锅炉燃料分级燃烧改造。对改造后锅炉进行了运行试验,结果表明,脱氮效果明显,锅炉效率也有提高。

【Abstract】 Adopting methods,such as lowering the total excess air ratio,increasing the share of burn up air(staged secondary air) and the kinetic pressure,as well as suitably increasing the tertiary air containing pulverized coal,etc.,retrofit of fuel staged burning for boiler no.3 in Wulashan Power Plant has been realized,and operation test of the retrofitted boiler being carried out.Results show that the effectiveness of denitrification is remarkable,and the boiler efficiency being also enhanced.

  • 【文献出处】 热力发电 ,Thermal Power Generation , 编辑部邮箱 ,2007年04期
  • 【分类号】TK223.2
  • 【被引频次】11
  • 【下载频次】122
节点文献中: 

本文链接的文献网络图示:

本文的引文网络