PLGA/HA支架材料生物相容性的动物实验研究

Study on Bio-compatibility of PLGA/HA in vivo

  • 推荐 CAJ下载
  • PDF下载
  • 不支持迅雷等下载工具,请取消加速工具后下载。

【作者】 张士杰裴庆国潘可风蒋欣泉张秀丽

【Author】 ZHANG Shi-jie1,2, PEI Qing-guo3, PAN Ke-feng1, JIANG Xin-quan4, ZHANG Xiu-li4 (1. Department of Oral and Maxillofacial Surgery, School of Stomatology, Tongji University, Shanghai 200072; 2. Department of Stomatology, Second Hospital, Shandong University, Jinan 250033, Shandong Province; 3. Department of Stomatology, First People’s Hospital, Medical College of Shanghai Jiaotong University, Shanghai 200080; 4. Lab of Oral Bio-engeering, Ninth People’s Hospital, Medical College of Shanghai Jiaotong University, Shanghai 200011, China)

【机构】 同济大学口腔医院口腔颌面外科上海交通大学附属第一人民医院口腔科上海交通大学医学院附属第九人民医院口腔生物工程实验室上海交通大学医学院附属第九人民医院口腔生物工程实验室 上海200072山东大学第二医院口腔科山东济南250033上海200080上海200072上海200011

【摘要】 目的:通过动物实验评价新型多孔聚乳酸乙醇酸/羟基磷灰石(polyaiticglycolic acid/hydroxyapatite,PLGA/HA)支架材料的生物相容性。方法:分别将5%和10%HA掺量的PLGA/HA支架材料注射到昆明小鼠腹腔内、植入到新西兰大白兔体内,选择全身毒性试验、亚急性毒性试验、血液相容性试验、肌肉刺激试验等,对其生物相容性进行评价。结果:全身急慢性毒性试验显示材料种植到小鼠及兔子体内后,动物一般情况良好,2周后体重、红细胞计数、白细胞计数等生理参数未见明显变化;实验显示两种材料对兔混合血浆凝血功能无影响;溶血试验结果显示5%和10%的PLGA/HA的溶血率分别为2.67%和3.62%,均小于5%,完全符合医用材料对溶血试验的要求;肌肉刺激试验结果显示两种材料埋植后局部未见红肿,4周时部分PLGA/HA材料开始降解,降解部分有大量的纤维结缔组织生长;HE染色结果显示PLGA/HA基本不存在抗原性,植入机体4周后,材料周围未见明显炎症细胞浸润。结论:5%和10%HA掺量的PLGA/HA均具有良好的生物相容性和体内安全性。

【Abstract】 Objective: To evaluate biological compatibility of a new porous polyaiticglycolic acid/hydroxyapatite(PLGA/HA) scaffold in animal experiment. Methods: PLGA/HA scaffold (with 5% HA or 10% HA) were injected into Kunming mice intraperitoneally and implanted into New Zealand rabbits. The biocompatibility experiments included systemic toxicity test, sub-acute toxicity test, blood compatibility test, and muscle stimulation test. Results: After injection and implantation of PLGA/HA scaffold into mice and rabbits, general condition of animals remained normal.Weight, red blood cell count, and white blood cell count of experimental animals altered slightly. Rabbit mixed plasma coagulation function wasn’t affected. Hemolytic rate of PLGA/HA scaffold with 5% HA or 10% HA were 2.67% and 3.62% respectively, which met the requirement of hemolysis test standard (<5%)as a medical material. Muscle stimulation test revealed that implantation did not cause any local redness. Part of PLGA/HA scaffold started to degrade at 4th week. There were little inflammatory cell infiltrations around the material 4 weeks after implantation. Conclusion: Both PLGA/HA scaffold with 5% HA or 10% HA have good biocompatibility.

【基金】 上海市科委基金重大项目(05DJ14006)
  • 【文献出处】 口腔颌面外科杂志 ,Journal of Oral and Maxillofacial Surgery , 编辑部邮箱 ,2007年01期
  • 【分类号】R318.08
  • 【被引频次】15
  • 【下载频次】462