节点文献

集成光电探测器绝对光谱响应度测试研究

Research the Development of Absolute Spectral Response for Integrated Photodetector

  • 推荐 CAJ下载
  • PDF下载
  • 不支持迅雷等下载工具,请取消加速工具后下载。

【作者】 陈世军袁红辉丁毅王欣

【Author】 CHEN Shi-jun,YUAN Hong-hui,DING Yi,WANG Xin(Shanghai Institute of Technical Physics,Chinese Academy of Sciences,Shanghai 200083,China)

【机构】 中国科学院上海技术物理研究所中国科学院上海技术物理研究所 上海200083上海200083

【摘要】 分析了光电探测器的结构及光谱响应度的测试原理,基于LabVIEW图形化软件,研制了一套0.2~1.1μm的光电探测器绝对光谱响应度测试装置。本系统采用单光路小光点标准替代法进行测量,系统组成灵活并可扩展,配合自行研制的驱动电路和采样保持电路,可以满足不同器件的需要。采用本系统对上海技物所研制的多种集成光电探测器的绝对光谱响应度进行测试,测试结果表明了系统的可行性。

【Abstract】 The structure and the testing principle of spectral response of photodetector were analyzed.A device used for testing absolute spectral response with wavelength ranged from 0.2μm to 1.1μm is developed by LabVIEW.This system used single optical channel substituted measurement methods,it is flexible and expandable with clock driver and sample and hold circuit that were developed by ourselves,it can satisfy the needs for measuring various devices.The experiment of testing integrated photodetector was achieved using this system.The result verifies to the feasible of this system.

  • 【文献出处】 激光与红外 ,Laser & Infrared , 编辑部邮箱 ,2007年08期
  • 【分类号】TN256
  • 【被引频次】5
  • 【下载频次】272
节点文献中: 

本文链接的文献网络图示:

本文的引文网络